Masimo Pronto-7 with sensor

MDEA Gold award

Pronto-7 — with rainbow 4D technology — for noninvasive and quick spot checking of total hemoglobin (SpHb®), oxygen saturation (SpO2), pulse rate (PR), and perfusion index (PI)

Your Solution for Hemoglobin Spot-checking

patient being monitored by medical professional with Masimo Pronto-7

The Pronto-7 may provide the following benefits:

  • > Facilitates timely patient assessment
  • > Easy-to-use — Improves efficiency
  • > Expands information available to your clinician at time of assessment

Four Simple Steps

front view of Masimo Pronto-7
measuring patient's finger to determine correct Masimo Pronto-7 sensor size

Select sensor size

placing noninvasive Masimo Pronto-7 sensor on patient's finger

Place sensor on finger

performing a spot-check with the Masimo Pronto-7

Press test button

Masimo Pronto-7 showing noninvasive spot-check results

Obtain results
Automatically saved — option to print,
e-mail, or manually record

SpHb Analytical Performance

chart comparing SpHb from Masimo Pronto-7 versus invasive tHb measurements from a laboratory reference device

In 11,335 comparisons of SpHb and invasive hemoglobin (tHb) measurements from a laboratory reference device, SpHb accuracy was as follows:*

  • -0.02 g/dL bias
  • 0.99 g/dL ARMS accuracy
  • Between 6 - 12 g/dL, greater than 95% of SpHb readings were within 2 g/dL of the laboratory tHb value
  • Between 12 - 18 g/dL, greater than 95% of SpHb readings were within 2 g/dL of the laboratory tHb value

*Masimo FDA 510(k) Submission Data using normal sensitivity mode.

Please note: These results were obtained in normal sensitivity mode following a specific protocol, in which all Directions for Use were followed and SpHb measurements were compared to validated laboratory reference measurements. Differences in results may be caused by many factors, such as those explained in Masimo’s Directions for Use. Some independent researchers have conducted their own testing and obtained similar results, while other researchers have reported larger differences when comparing SpHb measurements to laboratory measurements.

Pronto-7 In-service Training

Prior to using this device, the user should read and understand the Operator’s Manual and Directions for Use. Laboratory diagnostic tests using blood samples should be conducted prior to clinical decision making to completely understand the patient’s condition. Comparisons between SpHb measurements and laboratory diagnostic hemoglobin measurements may be affected by sample type, collection technique, physiological, and other factors.

Caution: Federal law restricts this device to sale by or on the order of a physician